Inverter surge versus boost ratings
A portable power station publishes two output numbers: continuous watts, and a higher peak. The peak is only useful against a motor if it is an inverter surge rating. Several manufacturers instead publish a boost figure for resistive loads (heaters, kettles, some tools), labelled X-Boost, Power Lifting, SurgePad, or similar. That number is stored in this database, and it is not used to decide whether a fridge compressor will start.
Why the difference matters
A compressor or a circular saw draws a brief inrush several times its running wattage. The inverter has to survive that instant. A resistive boost path is a different circuit: it can raise the ceiling for a heater without describing how the inverter behaves against a motor. Treating the two as the same produces a confidently wrong recommendation on exactly the load that gets a unit returned.
The calculator, the refrigerator pages, and the scenario pages all call the same function. If the peak is a boost rating, a motor start is reported as unverified, not as cleared. The wording in the table is a short citation from the manufacturer page, not a lab measurement.
Current models, grouped by what the peak means
30 current models publish an inverter surge. 45 publish a boost figure instead. 75 of 75 rows carry a source citation. Recheck is 90 days after the page was read. A stale date means the wording should be read again, not that the ruling is void.
Boost rating, not used against motor starts
The calculator will not clear a compressor or a saw against these peaks.
| Model | Printed peak | Ruling | Source wording | Read | Recheck |
|---|---|---|---|---|---|
| EcoFlow DELTA 2 | 2,200 W | Boost, not motor start | *"No overloading for high-wattage appliances (up to 2200W) with X-Boost mode."Source | 2026-10-10 | 2027-01-08 |
| EcoFlow DELTA 2 Max | 3,400 W | Boost, not motor start | "X-Boost proprietary technology, run appliances with an output of up to 3400W."Source | 2026-10-10 | 2027-01-08 |
| BLUETTI AC180 | 2,700 W | Boost, not motor start | "Power Lifting Mode allows AC180 to run high-power heating devices up to 2,700W."Source | 2026-10-10 | 2027-01-08 |
| BLUETTI AC70 | 2,000 W | Boost, not motor start | "The Power Lifting Mode only works for resistive loads of up to 2,000W."Source | 2026-10-10 | 2027-01-08 |
| Anker SOLIX C1000 | 2,400 W | Boost, not motor start | "Heat-generating devices work best. SurgePad™ does not support precision instruments…"Source | 2026-10-10 | 2027-01-08 |
| Anker SOLIX C300 | 600 W | Boost, not motor start | "300W rated power to connected devices (600W with SurgePad)."Source | 2026-10-10 | 2027-01-08 |
| Anker SOLIX C2000 Gen 2 | 4,000 W | Boost, not motor start | "Massive 4,000W Peak Power: … 2,400W rated power and up to 4,000W peak."Source | 2026-10-10 | 2027-01-08 |
| Anker SOLIX F2600 | 2,800 W | Boost, not motor start | Spec: "AC Surge Output: 2800W."Source | 2026-10-10 | 2027-01-08 |
| Anker SOLIX C1000 Gen 2 | 3,000 W | Boost, not motor start | "2,000W (3,000W Peak Output)."Source | 2026-10-10 | 2027-01-08 |
| BLUETTI Elite 200 V2 | 3,900 W | Boost, not motor start | "kick into 3900W Power Lifting mode for pure resistive loads."Source | 2026-10-10 | 2027-01-08 |
| BLUETTI Elite 30 V2 | 1,500 W | Boost, not motor start | "When it comes to pure resistive devices, it can momentarily reach up to 1,500W."Source | 2026-10-10 | 2027-01-08 |
| BLUETTI Elite 400 | 3,900 W | Boost, not motor start | "2,600 W rated / 3,900 W Lifting Power."Source | 2026-10-10 | 2027-01-08 |
| BLUETTI AC180P | 2,700 W | Boost, not motor start | "In this mode, AC180P can run high-power heating devices up to 2,700W."Source | 2026-10-10 | 2027-01-08 |
| BLUETTI AC60 | 1,200 W | Boost, not motor start | "Power Lifting Mode allows AC60 / AC60P to run high-power heating devices up to 1,200W."Source | 2026-10-10 | 2027-01-08 |
| BLUETTI AC50B | 1,000 W | Boost, not motor start | "*Ideal for running pure resistive loads under 1,000W."Source | 2026-10-10 | 2027-01-08 |
| BLUETTI Elite 100 mini | 700 W | Boost, not motor start | "*Total output not to exceed 700W." No separate surge figure.Source | 2026-10-10 | 2027-01-08 |
| BLUETTI AC2A | 600 W | Boost, not motor start | "Power Lifting Mode allows AC2A to run high-power heating devices up to 600W."Source | 2026-10-10 | 2027-01-08 |
| BLUETTI Pioneer Na | 2,250 W | Boost, not motor start | "2,250 W lifting power for high-demand appliances."Source | 2026-10-10 | 2027-01-08 |
| BLUETTI Apex 300 | 7,680 W | Boost, not motor start | "3,840W Output 7,680W Lifting Power."Source | 2026-10-10 | 2027-01-08 |
| BLUETTI AC50P | 1,200 W | Boost, not motor start | "The power lifting mode supports pure resistance devices like kettles and irons under 1200W."Source | 2026-10-10 | 2027-01-08 |
| Jackery HomePower 2000 Plus v2 | 2,400 W | Boost, not motor start | Nav/spec: "2048Wh Capacity | 2400W Output." No separate inverter-surge figure.Source | 2026-10-10 | 2027-01-08 |
| Anker SOLIX C300X | 600 W | Boost, not motor start | "300W rated power to connected devices (600W with SurgePad)."Source | 2026-10-10 | 2027-01-08 |
| Anker SOLIX S2000 | 3,000 W | Boost, not motor start | "1,500W Rated | 3,000W Peak | Pure Sine Wave AC."Source | 2026-10-10 | 2027-01-08 |
| BLUETTI AC200P L | 3,600 W | Boost, not motor start | "run power-hungry heating devices up to 3,600W."Source | 2026-10-10 | 2027-01-08 |
| BLUETTI Handsfree 1 | 450 W | Boost, not motor start | Spec table: "Lifting Power: 450W."Source | 2026-10-10 | 2027-01-08 |
| Jackery Explorer 100 Plus | 128 W | Boost, not motor start | "Mini Jackery Portable Power Station, 99Wh, 128W" and runtime tool "not exceeding 128W." No separate surge figure.Source | 2026-10-10 | 2027-01-08 |
| Anker SOLIX C800 | 1,600 W | Boost, not motor start | "SurgePad activates when total output exceeds rate output. It works best with heat-generating devices."Source | 2026-10-10 | 2027-01-08 |
| BLUETTI Handsfree 2 | 1,200 W | Boost, not motor start | Spec table: "Lifting Power: 1200W."Source | 2026-10-10 | 2027-01-08 |
| Anker SOLIX 521 PowerHouse | 200 W | Boost, not motor start | Title: "256Wh | 200W." No separate surge figure.Source | 2026-10-10 | 2027-01-08 |
| Anker SOLIX 522 PowerHouse | 600 W | Boost, not motor start | "you're still running appliances up to 600W with SurgePad" — heating rods or a kettle.Source | 2026-10-10 | 2027-01-08 |
| Anker SOLIX 535 PowerHouse | 500 W | Boost, not motor start | Spec: "AC Output/AC: 110V~ 4.54A, 50Hz/60Hz, 500W." No separate surge figure.Source | 2026-10-10 | 2027-01-08 |
| Anker SOLIX 555 PowerHouse | 1,000 W | Boost, not motor start | Spec: "AC Output: 110V~ 9.09A, 50Hz/60Hz, 1000W." No separate surge figure.Source | 2026-10-10 | 2027-01-08 |
| Anker SOLIX C1000X | 2,400 W | Boost, not motor start | "Heat-generating devices work best. SurgePad™ does not support precision instruments…"Source | 2026-10-10 | 2027-01-08 |
| BLUETTI Elite 10 Mini | 200 W | Boost, not motor start | "Mini but Mighty: 128Wh capacity with 200W AC output." No separate surge figure.Source | 2026-10-10 | 2027-01-08 |
| Anker SOLIX F2000 | 2,300 W | Boost, not motor start | "2048Wh capacity and 2300W AC output." No separate surge figure.Source | 2026-10-10 | 2027-01-08 |
| Anker SOLIX C800 Plus | 1,600 W | Boost, not motor start | "SurgePad activates when total output exceeds rate output. It works best with heat-generating devices."Source | 2026-10-10 | 2027-01-08 |
| EcoFlow RIVER 3 | 600 W | Boost, not motor start | "RIVER 3: 300W power station | X-Boost to 600W."Source | 2026-10-10 | 2027-01-08 |
| EcoFlow RIVER 3 Max | 1,200 W | Boost, not motor start | "X-Boost technology can continuously handle 1200W heating devices."Source | 2026-10-10 | 2027-01-08 |
| EcoFlow RIVER 3 Max Plus | 1,200 W | Boost, not motor start | "RIVER 3 Max Plus… 600W Output | 1200W X-Boost."Source | 2026-10-10 | 2027-01-08 |
| EcoFlow RIVER 2 | 450 W | Boost, not motor start | "RIVER 2は定格AC出力300W・X-Boost 450W"Source | 2026-10-10 | 2027-01-08 |
| EcoFlow DELTA Pro | 4,500 W | Boost, not motor start | "Use a single unit to power up to 4500W¹ of appliances." Footnote: "¹ With X-Boost mode turned on."Source | 2026-10-10 | 2027-01-08 |
| Jackery HomePower 3600 Plus | 3,600 W | Boost, not motor start | "Power Your Essentials for Weeks: 3600W output and 3584Wh capacity." No separate inverter-surge figure.Source | 2026-10-10 | 2027-01-08 |
| Jackery HomePower 3600 Pro Max | 4,000 W | Boost, not motor start | Nav: "3584Wh Capacity | 4000W Output" and "2KW@120V | 4KW@240V." Not labelled inverter surge.Source | 2026-10-10 | 2027-01-08 |
| Anker SOLIX C200X | 600 W | Boost, not motor start | "300W rated power to connected devices (600W with SurgePad)."Source | 2026-10-10 | 2027-01-08 |
| Jackery HomePower 1000 Plus v2 | 3,600 W | Boost, not motor start | "1800 W Rated Output 3600 W Peak." Marketing copy also says "3600W surge" for tools; the spec block still labels Peak.Source | 2026-10-10 | 2027-01-08 |
Inverter surge, used against motor starts
These peaks are checked against compressor and tool inrush. A pass is still an estimate, not a lab start.
| Model | Printed peak | Ruling | Source wording | Read | Recheck |
|---|---|---|---|---|---|
| Jackery Explorer 300 | 500 W | Inverter surge | Spec: "500W surge"Source | 2026-09-30 | 2026-12-29 |
| Jackery Explorer 300 v2 | 600 W | Inverter surge | Spec: "600W surge"Source | 2026-09-30 | 2026-12-29 |
| Jackery Explorer 1000 v2 | 3,000 W | Inverter surge | Spec: "3000W surge"Source | 2026-09-30 | 2026-12-29 |
| Jackery Explorer 1000 Plus | 4,000 W | Inverter surge | Spec: "4000W surge"Source | 2026-09-30 | 2026-12-29 |
| Jackery Explorer 1500 Ultra | 3,600 W | Inverter surge | Spec: "3600W surge"Source | 2026-09-30 | 2026-12-29 |
| Jackery Explorer 2000 v2 | 4,400 W | Inverter surge | Spec: "4400W surge"Source | 2026-09-30 | 2026-12-29 |
| Jackery Explorer 2000 Plus | 6,000 W | Inverter surge | Spec: "6000W surge"Source | 2026-09-30 | 2026-12-29 |
| Jackery HomePower 3000 | 7,200 W | Inverter surge | Spec: "7200W surge"Source | 2026-09-30 | 2026-12-29 |
| Jackery Explorer 5000 Plus | 14,400 W | Inverter surge | Spec: "14400W surge"Source | 2026-09-30 | 2026-12-29 |
| BLUETTI Elite 100 V2 | 3,600 W | Inverter surge | Labelled "Surge Power 3,600W"Source | 2026-09-30 | 2026-12-29 |
| EcoFlow RIVER 2 Max 500 | 1,000 W | Inverter surge | Spec: "Surge 1000W"Source | 2026-09-30 | 2026-12-29 |
| EcoFlow RIVER 2 Max | 1,000 W | Inverter surge | Spec: "Surge 1000W"Source | 2026-09-30 | 2026-12-29 |
| EcoFlow RIVER 2 Pro | 1,600 W | Inverter surge | Spec: "Surge 1600W"Source | 2026-09-30 | 2026-12-29 |
| EcoFlow RIVER 3 Plus | 1,200 W | Inverter surge | Labelled "surge"; X-Boost listed separatelySource | 2026-09-30 | 2026-12-29 |
| EcoFlow DELTA 3 | 3,600 W | Inverter surge | Spec: "Surge 3600W"Source | 2026-09-30 | 2026-12-29 |
| EcoFlow DELTA 3 Classic | 3,600 W | Inverter surge | Spec: "3600W surge"Source | 2026-09-30 | 2026-12-29 |
| EcoFlow DELTA 3 Plus | 3,600 W | Inverter surge | Spec: "3600W surge"Source | 2026-09-30 | 2026-12-29 |
| EcoFlow DELTA 3 Max | 4,800 W | Inverter surge | Spec: "4800W surge"Source | 2026-09-30 | 2026-12-29 |
| EcoFlow DELTA 3 Max Plus | 6,000 W | Inverter surge | Spec: "6000W surge"Source | 2026-09-30 | 2026-12-29 |
| EcoFlow DELTA 3 Ultra | 7,200 W | Inverter surge | Spec: "Surge 7200W"Source | 2026-09-30 | 2026-12-29 |
| Anker SOLIX F3000 | 7,200 W | Inverter surge | Labelled "Surge Power 7,200W"Source | 2026-10-05 | 2027-01-03 |
| Anker SOLIX F3800 | 9,000 W | Inverter surge | Labelled "AC surge output 9,000W"Source | 2026-10-05 | 2027-01-03 |
| Anker SOLIX F3800 Plus | 6,000 W | Inverter surge | No separate inverter-surge figure on the source pageSource | 2026-10-05 | 2027-01-03 |
| EcoFlow DELTA 3 Ultra Plus | 7,200 W | Inverter surge | Spec: "Surge 7200W"Source | 2026-10-05 | 2027-01-03 |
| BLUETTI AC200MAX | 4,800 W | Inverter surge | Spec: "4,800W surge"Source | 2026-10-05 | 2027-01-03 |
| BLUETTI AC200P | 4,800 W | Inverter surge | Spec: "4,800W surge"Source | 2026-10-05 | 2027-01-03 |
| BLUETTI FridgePower | 3,600 W | Inverter surge | Spec: "3,600W surge"Source | 2026-10-05 | 2027-01-03 |
| BLUETTI EB70S | 1,400 W | Inverter surge | Labelled "Surge Power 1,400W"Source | 2026-10-05 | 2027-01-03 |
| Jackery Explorer 600 v2 | 1,000 W | Inverter surge | Spec: "1000W surge"Source | 2026-10-05 | 2027-01-03 |
| Jackery Explorer 1500 v2 | 4,000 W | Inverter surge | Spec: "4000W surge"Source | 2026-10-05 | 2027-01-03 |
Discontinued records (4), not on the recheck clock
Last read on the date shown. These rows are not rechecked. The ruling stays so an old station page does not silently treat a boost figure as surge.
- BLUETTI EB3A · inverter surge · 1,200 W · read 2026-09-30 · Spec: "1,200W surge"
- BLUETTI AC180T · boost · 2,700 W · read 2026-10-05 · Labelled "Power Lifting"; page limits it to resistive loads
- BLUETTI AC240 · boost · 3,600 W · read 2026-10-05 · Labelled "Power Lifting", not inverter surge
- Anker SOLIX F1500 · boost · 2,400 W · read 2026-10-10 · Last UK spec table: "AC Surge Output 2400W." US and UK manufacturer URLs returned 404 on 2026-10-10.
Each refrigerator page restates this for one model. If a manufacturer page changes the wording, the ruling is updated on the next verification and the calculator follows the same record. Brand hubs:Ecoflow, Jackery, Bluetti, Anker SOLIX.