Skip to content

Inverter surge versus boost ratings

A portable power station publishes two output numbers: continuous watts, and a higher peak. The peak is only useful against a motor if it is an inverter surge rating. Several manufacturers instead publish a boost figure for resistive loads (heaters, kettles, some tools), labelled X-Boost, Power Lifting, SurgePad, or similar. That number is stored in this database, and it is not used to decide whether a fridge compressor will start.

Why the difference matters

A compressor or a circular saw draws a brief inrush several times its running wattage. The inverter has to survive that instant. A resistive boost path is a different circuit: it can raise the ceiling for a heater without describing how the inverter behaves against a motor. Treating the two as the same produces a confidently wrong recommendation on exactly the load that gets a unit returned.

The calculator, the refrigerator pages, and the scenario pages all call the same function. If the peak is a boost rating, a motor start is reported as unverified, not as cleared. The wording in the table is a short citation from the manufacturer page, not a lab measurement.

Current models, grouped by what the peak means

30 current models publish an inverter surge. 45 publish a boost figure instead. 75 of 75 rows carry a source citation. Recheck is 90 days after the page was read. A stale date means the wording should be read again, not that the ruling is void.

Boost rating, not used against motor starts

The calculator will not clear a compressor or a saw against these peaks.

ModelPrinted peakRulingSource wordingReadRecheck
EcoFlow DELTA 22,200 WBoost, not motor start*"No overloading for high-wattage appliances (up to 2200W) with X-Boost mode."Source2026-10-102027-01-08
EcoFlow DELTA 2 Max3,400 WBoost, not motor start"X-Boost proprietary technology, run appliances with an output of up to 3400W."Source2026-10-102027-01-08
BLUETTI AC1802,700 WBoost, not motor start"Power Lifting Mode allows AC180 to run high-power heating devices up to 2,700W."Source2026-10-102027-01-08
BLUETTI AC702,000 WBoost, not motor start"The Power Lifting Mode only works for resistive loads of up to 2,000W."Source2026-10-102027-01-08
Anker SOLIX C10002,400 WBoost, not motor start"Heat-generating devices work best. SurgePad™ does not support precision instruments…"Source2026-10-102027-01-08
Anker SOLIX C300600 WBoost, not motor start"300W rated power to connected devices (600W with SurgePad)."Source2026-10-102027-01-08
Anker SOLIX C2000 Gen 24,000 WBoost, not motor start"Massive 4,000W Peak Power: … 2,400W rated power and up to 4,000W peak."Source2026-10-102027-01-08
Anker SOLIX F26002,800 WBoost, not motor startSpec: "AC Surge Output: 2800W."Source2026-10-102027-01-08
Anker SOLIX C1000 Gen 23,000 WBoost, not motor start"2,000W (3,000W Peak Output)."Source2026-10-102027-01-08
BLUETTI Elite 200 V23,900 WBoost, not motor start"kick into 3900W Power Lifting mode for pure resistive loads."Source2026-10-102027-01-08
BLUETTI Elite 30 V21,500 WBoost, not motor start"When it comes to pure resistive devices, it can momentarily reach up to 1,500W."Source2026-10-102027-01-08
BLUETTI Elite 4003,900 WBoost, not motor start"2,600 W rated / 3,900 W Lifting Power."Source2026-10-102027-01-08
BLUETTI AC180P2,700 WBoost, not motor start"In this mode, AC180P can run high-power heating devices up to 2,700W."Source2026-10-102027-01-08
BLUETTI AC601,200 WBoost, not motor start"Power Lifting Mode allows AC60 / AC60P to run high-power heating devices up to 1,200W."Source2026-10-102027-01-08
BLUETTI AC50B1,000 WBoost, not motor start"*Ideal for running pure resistive loads under 1,000W."Source2026-10-102027-01-08
BLUETTI Elite 100 mini700 WBoost, not motor start"*Total output not to exceed 700W." No separate surge figure.Source2026-10-102027-01-08
BLUETTI AC2A600 WBoost, not motor start"Power Lifting Mode allows AC2A to run high-power heating devices up to 600W."Source2026-10-102027-01-08
BLUETTI Pioneer Na2,250 WBoost, not motor start"2,250 W lifting power for high-demand appliances."Source2026-10-102027-01-08
BLUETTI Apex 3007,680 WBoost, not motor start"3,840W Output 7,680W Lifting Power."Source2026-10-102027-01-08
BLUETTI AC50P1,200 WBoost, not motor start"The power lifting mode supports pure resistance devices like kettles and irons under 1200W."Source2026-10-102027-01-08
Jackery HomePower 2000 Plus v22,400 WBoost, not motor startNav/spec: "2048Wh Capacity | 2400W Output." No separate inverter-surge figure.Source2026-10-102027-01-08
Anker SOLIX C300X600 WBoost, not motor start"300W rated power to connected devices (600W with SurgePad)."Source2026-10-102027-01-08
Anker SOLIX S20003,000 WBoost, not motor start"1,500W Rated | 3,000W Peak | Pure Sine Wave AC."Source2026-10-102027-01-08
BLUETTI AC200P L3,600 WBoost, not motor start"run power-hungry heating devices up to 3,600W."Source2026-10-102027-01-08
BLUETTI Handsfree 1450 WBoost, not motor startSpec table: "Lifting Power: 450W."Source2026-10-102027-01-08
Jackery Explorer 100 Plus128 WBoost, not motor start"Mini Jackery Portable Power Station, 99Wh, 128W" and runtime tool "not exceeding 128W." No separate surge figure.Source2026-10-102027-01-08
Anker SOLIX C8001,600 WBoost, not motor start"SurgePad activates when total output exceeds rate output. It works best with heat-generating devices."Source2026-10-102027-01-08
BLUETTI Handsfree 21,200 WBoost, not motor startSpec table: "Lifting Power: 1200W."Source2026-10-102027-01-08
Anker SOLIX 521 PowerHouse200 WBoost, not motor startTitle: "256Wh | 200W." No separate surge figure.Source2026-10-102027-01-08
Anker SOLIX 522 PowerHouse600 WBoost, not motor start"you're still running appliances up to 600W with SurgePad" — heating rods or a kettle.Source2026-10-102027-01-08
Anker SOLIX 535 PowerHouse500 WBoost, not motor startSpec: "AC Output/AC: 110V~ 4.54A, 50Hz/60Hz, 500W." No separate surge figure.Source2026-10-102027-01-08
Anker SOLIX 555 PowerHouse1,000 WBoost, not motor startSpec: "AC Output: 110V~ 9.09A, 50Hz/60Hz, 1000W." No separate surge figure.Source2026-10-102027-01-08
Anker SOLIX C1000X2,400 WBoost, not motor start"Heat-generating devices work best. SurgePad™ does not support precision instruments…"Source2026-10-102027-01-08
BLUETTI Elite 10 Mini200 WBoost, not motor start"Mini but Mighty: 128Wh capacity with 200W AC output." No separate surge figure.Source2026-10-102027-01-08
Anker SOLIX F20002,300 WBoost, not motor start"2048Wh capacity and 2300W AC output." No separate surge figure.Source2026-10-102027-01-08
Anker SOLIX C800 Plus1,600 WBoost, not motor start"SurgePad activates when total output exceeds rate output. It works best with heat-generating devices."Source2026-10-102027-01-08
EcoFlow RIVER 3600 WBoost, not motor start"RIVER 3: 300W power station | X-Boost to 600W."Source2026-10-102027-01-08
EcoFlow RIVER 3 Max1,200 WBoost, not motor start"X-Boost technology can continuously handle 1200W heating devices."Source2026-10-102027-01-08
EcoFlow RIVER 3 Max Plus1,200 WBoost, not motor start"RIVER 3 Max Plus… 600W Output | 1200W X-Boost."Source2026-10-102027-01-08
EcoFlow RIVER 2450 WBoost, not motor start"RIVER 2は定格AC出力300W・X-Boost 450W"Source2026-10-102027-01-08
EcoFlow DELTA Pro4,500 WBoost, not motor start"Use a single unit to power up to 4500W¹ of appliances." Footnote: "¹ With X-Boost mode turned on."Source2026-10-102027-01-08
Jackery HomePower 3600 Plus3,600 WBoost, not motor start"Power Your Essentials for Weeks: 3600W output and 3584Wh capacity." No separate inverter-surge figure.Source2026-10-102027-01-08
Jackery HomePower 3600 Pro Max4,000 WBoost, not motor startNav: "3584Wh Capacity | 4000W Output" and "2KW@120V | 4KW@240V." Not labelled inverter surge.Source2026-10-102027-01-08
Anker SOLIX C200X600 WBoost, not motor start"300W rated power to connected devices (600W with SurgePad)."Source2026-10-102027-01-08
Jackery HomePower 1000 Plus v23,600 WBoost, not motor start"1800 W Rated Output 3600 W Peak." Marketing copy also says "3600W surge" for tools; the spec block still labels Peak.Source2026-10-102027-01-08

Inverter surge, used against motor starts

These peaks are checked against compressor and tool inrush. A pass is still an estimate, not a lab start.

ModelPrinted peakRulingSource wordingReadRecheck
Jackery Explorer 300500 WInverter surgeSpec: "500W surge"Source2026-09-302026-12-29
Jackery Explorer 300 v2600 WInverter surgeSpec: "600W surge"Source2026-09-302026-12-29
Jackery Explorer 1000 v23,000 WInverter surgeSpec: "3000W surge"Source2026-09-302026-12-29
Jackery Explorer 1000 Plus4,000 WInverter surgeSpec: "4000W surge"Source2026-09-302026-12-29
Jackery Explorer 1500 Ultra3,600 WInverter surgeSpec: "3600W surge"Source2026-09-302026-12-29
Jackery Explorer 2000 v24,400 WInverter surgeSpec: "4400W surge"Source2026-09-302026-12-29
Jackery Explorer 2000 Plus6,000 WInverter surgeSpec: "6000W surge"Source2026-09-302026-12-29
Jackery HomePower 30007,200 WInverter surgeSpec: "7200W surge"Source2026-09-302026-12-29
Jackery Explorer 5000 Plus14,400 WInverter surgeSpec: "14400W surge"Source2026-09-302026-12-29
BLUETTI Elite 100 V23,600 WInverter surgeLabelled "Surge Power 3,600W"Source2026-09-302026-12-29
EcoFlow RIVER 2 Max 5001,000 WInverter surgeSpec: "Surge 1000W"Source2026-09-302026-12-29
EcoFlow RIVER 2 Max1,000 WInverter surgeSpec: "Surge 1000W"Source2026-09-302026-12-29
EcoFlow RIVER 2 Pro1,600 WInverter surgeSpec: "Surge 1600W"Source2026-09-302026-12-29
EcoFlow RIVER 3 Plus1,200 WInverter surgeLabelled "surge"; X-Boost listed separatelySource2026-09-302026-12-29
EcoFlow DELTA 33,600 WInverter surgeSpec: "Surge 3600W"Source2026-09-302026-12-29
EcoFlow DELTA 3 Classic3,600 WInverter surgeSpec: "3600W surge"Source2026-09-302026-12-29
EcoFlow DELTA 3 Plus3,600 WInverter surgeSpec: "3600W surge"Source2026-09-302026-12-29
EcoFlow DELTA 3 Max4,800 WInverter surgeSpec: "4800W surge"Source2026-09-302026-12-29
EcoFlow DELTA 3 Max Plus6,000 WInverter surgeSpec: "6000W surge"Source2026-09-302026-12-29
EcoFlow DELTA 3 Ultra7,200 WInverter surgeSpec: "Surge 7200W"Source2026-09-302026-12-29
Anker SOLIX F30007,200 WInverter surgeLabelled "Surge Power 7,200W"Source2026-10-052027-01-03
Anker SOLIX F38009,000 WInverter surgeLabelled "AC surge output 9,000W"Source2026-10-052027-01-03
Anker SOLIX F3800 Plus6,000 WInverter surgeNo separate inverter-surge figure on the source pageSource2026-10-052027-01-03
EcoFlow DELTA 3 Ultra Plus7,200 WInverter surgeSpec: "Surge 7200W"Source2026-10-052027-01-03
BLUETTI AC200MAX4,800 WInverter surgeSpec: "4,800W surge"Source2026-10-052027-01-03
BLUETTI AC200P4,800 WInverter surgeSpec: "4,800W surge"Source2026-10-052027-01-03
BLUETTI FridgePower3,600 WInverter surgeSpec: "3,600W surge"Source2026-10-052027-01-03
BLUETTI EB70S1,400 WInverter surgeLabelled "Surge Power 1,400W"Source2026-10-052027-01-03
Jackery Explorer 600 v21,000 WInverter surgeSpec: "1000W surge"Source2026-10-052027-01-03
Jackery Explorer 1500 v24,000 WInverter surgeSpec: "4000W surge"Source2026-10-052027-01-03
Discontinued records (4), not on the recheck clock

Last read on the date shown. These rows are not rechecked. The ruling stays so an old station page does not silently treat a boost figure as surge.

  • BLUETTI EB3A · inverter surge · 1,200 W · read 2026-09-30 · Spec: "1,200W surge"
  • BLUETTI AC180T · boost · 2,700 W · read 2026-10-05 · Labelled "Power Lifting"; page limits it to resistive loads
  • BLUETTI AC240 · boost · 3,600 W · read 2026-10-05 · Labelled "Power Lifting", not inverter surge
  • Anker SOLIX F1500 · boost · 2,400 W · read 2026-10-10 · Last UK spec table: "AC Surge Output 2400W." US and UK manufacturer URLs returned 404 on 2026-10-10.

Each refrigerator page restates this for one model. If a manufacturer page changes the wording, the ruling is updated on the next verification and the calculator follows the same record. Brand hubs:Ecoflow, Jackery, Bluetti, Anker SOLIX.