Three things decide whether an estimate is useful: the formula, the constants, and where the inputs come from. All three are written here so you can disagree with any of them. The same functions size the homepage calculator, the scenario pages, and each station's refrigerator verdict. If those surfaces ever disagree, that is a bug. Emailhello@powerstationsize.com.

The formulas

Daily energy per device

watts x hours x duty cycle

Duty cycle is the share of the hour a device actually draws power. A fridge compressor might run 35 percent of the time, so its nameplate wattage overstates its average draw. A router runs continuously, so its duty cycle is 1. The calculator lets you edit all three numbers on every row.

Recommended nameplate capacity

(daily Wh / inverter efficiency) x reserve margin

The inverter converts battery DC to household AC at a loss. Dividing by efficiency makes that loss increase the battery you should shop for, instead of ignoring it. The reserve covers ageing, cold weather, and the gap between a lab figure and a house. Defaults are 0.85 and 1.20. The tool exposes 0.80 / 0.85 / 0.90 and 1.15 / 1.20 / 1.35.

Surge check

max(single device surge) <= station inverter surge

The check compares only the largest recorded single-device startup surge with the station rating. It does not add other running loads, simultaneous starts, or surge duration. A passing estimate is not confirmation that a device will start. If the station only publishes a resistive boost (X-Boost, Power Lifting, SurgePad), that peak is not used. A known motor surge is then surge_unverified, not cleared.

Continuous output check

sum(device watts) <= station continuous output

If several devices run at once, the simultaneous draw must stay under the continuous rating. The "if all at once" hours assume every device draws the entered watts with no duty-cycle reduction. This is a comparison estimate, not a guaranteed minimum runtime.

Default constants

Inverter efficiency
0.85
Reserve margin
1.20
Usable capacity
0.85

The runtime calculator multiplies nameplate watt-hours by 0.85before dividing by average draw. This is a combined planning allowance for usable battery energy, conversion losses, and self-consumption, not a measured value for every model or a statement about its output voltage. It does not apply the sizing calculator's inverter efficiency factor a second time. Actual usable energy varies with the station and load.

Worked example

Fridge outage load used on this site: a full-size refrigerator at 150 W for 8 hours at 35 percent duty (420 Wh), a router at 12 W for 8 hours (96 Wh), an LED lamp at 9 W for 5 hours (45 Wh), and a phone at 12 W for 2 hours (24 Wh). Daily energy before conversion is 585 Wh.

Recommended nameplate is 585 / 0.85 x 1.20, which is 826 Wh. Startup surge on that fridge row is 1,200 W. A station whose only peak is a resistive boost is excluded from the match list even if its watt-hours are enough. That is the failure this site exists to make visible before you buy.

CPAP without a humidifier is treated as 45 W for 8 hours (360 Wh) plus a phone charge, 384 Wh daily, 542 Wh nameplate after loss and reserve. Startup inrush is not modelled in this example; check the equipment and adapter requirements. The 80 W humidifier-on entry represents the entire CPAP with heating, not an extra 80 W accessory. Choose one configuration per machine, not both. These are illustrative inputs, not prescribed therapy settings.

Solar, if you recharge off grid

Panel watts needed to replace a day's draw is daily Wh / (peak sun hours x inverter efficiency). The default sun figure is 5 hours. The calculator also accepts an array you already have and reports how much of the day that array covers, using the same efficiency. Panel nameplate is not charge rate. Angle, cloud, season, and heat all reduce output. Treat solar as a top-up, not as a way to run a 1,500 W heater indefinitely. This simplified energy model reuses the efficiency setting; it does not separately model panel, controller, battery, and inverter losses. A wattage match alone does not verify panel voltage, current, polarity, connector compatibility, or the station's operating limits.

Where inputs come from

Station specifications

The manufacturer product page. Each model stores the source URL and the date it was verified. A reading older than 90 days is flagged on the model page. If the manufacturer page and this site disagree, the manufacturer page wins.

Device power ranges

Manufacturer documentation where a figure is published, otherwise engineering ranges. Each device entry records which it is. You can override watts, hours, and duty cycle before you trust a result.

What we do not claim

We do not publish our own runtime test results. Every hour on this site is calculated, not measured. We do not rate a station as a medical device. Whole-home backup needs a manufacturer-approved, code-compliant transfer or isolation system; this calculator does not design that installation.

Known limitations