Can the EcoFlow RIVER 3 Max run a refrigerator?

EcoFlow RIVER 3 Max does not publish an inverter surge, so this fridge start is not cleared.

The fridge numbers are an estimated engineering range from the device library, not a measurement of your compressor.

Source:www.ecoflow.com. Verified 2026-10-10. Numbers are copied from that page, not from a lab test.

The check

Binding limit
Unverified boost
Estimated cycling runtime
Not applicable until it can start and run

Usable capacity 486 Wh at 85 percent of nameplate, divided by 52.5 W average draw.

What was compared

Fridge load versus this station
CheckThis fridge loadThis station
Running watts150 W nameplate600 W continuous
Startup1,200 W estimated inrush1,200 W boost, not inverter surge
Energy420 Wh over 8 h at 35 percent duty572 Wh nameplate

What that means

Startup not checked. The 1,200 W peak is a boost rating ("X-Boost technology can continuously handle 1200W heating devices."), read 2026-10-10. Continuous output (600 W) is enough for the 150 W running draw, and capacity is a separate question once a motor start is actually verified. Seesurge versus boost.